Analog inputs
Basics¶
The TGZ servo amplifier has two analogue inputs for general use integrated on the X8 connector in the standard (UNI) version. These are inputs with a nominal input voltage range of 0-10V against the common terminal AGND.
Parameters¶
Input no. | voltage range | nominal input resistance ±10% | time constant ±10% |
---|---|---|---|
# | Vin | RinNom | τin |
- | V | kΩ | us |
1 | 0-10 | 11 | 22 |
2 | 0-10 | 11 | 22 |