Analog inputs
Basics¶
The TGZ servo amplifier has two analogue inputs for general use integrated on the X8 connector in the standard (UNI) version. These are inputs with a nominal input voltage range of 0~10V against the common terminal AGND.
Parameters¶
| Input no. | voltage range | nominal input resistance ±10% | time constant ±10% |
|---|---|---|---|
| # | Vin | RinNom | τin |
| - | V | kΩ | us |
| 1 | 0-10 | 11 | 22 |
| 2 | 0-10 | 11 | 22 |