Skip to content

Analog inputs

Basics

The TGZ servo amplifier has two analogue inputs for general use integrated on the X8 connector in the standard (UNI) version. These are inputs with a nominal input voltage range of 0-10V against the common terminal AGND.

Parameters

Input no. voltage range nominal input resistance ±10% time constant ±10%
# Vin RinNom τin
- V us
1 0-10 11 22
2 0-10 11 22