Parameters
POWER SUPPLY | |
---|---|
Control voltage | 24 VDC ± 10 %, 600 mA |
Power supply voltage | 3 x 400 VAC/50Hz 20A |
Installed power consumption for S1 operation | 7,9 kVA |
Constant current on one axis | 14 A |
Maximum output current (max. 5s) | 30 A |
Losses at rated load | 110 W |
Switching frequency | 10 kHz |
Protection level | IP20 |
Ambient operating temperature | -32 ~ +40 °C |
COMMUNICATION | |
ETHERNET UDP (service) | 100/1000 Mb/s, 1 x 8pin MOLEX 5031490800 CLIK-MATE 1.5 |
I/O | |
8 DI, 6 DO | 1 x 18pin MOLEX 5031491800 CLIK-MATE 1.5 |
3 DI, 1 AI, 2 PT1000 | 1 x 12pin MOLEX 5031491200 CLIK-MATE 1.5 |
FEEDBACK | |
FB1, FB2, FB3 | 3 x 10pin MOLEX 5031481090 CLIK-MATE 1.5 |
FBE | 1 x 12pin MOLEX 5031481290 CLIK-MATE 1.5 |
SIGNALING | |
LED display | Error message, 2x7 LED segment |
LED signaling | 1x green (SERVO OK) 1x red (SERVO ERROR) 1x green (ECAT RUN) |
OTHER CONNECTORS | |
Power supply of the power section | 1 x 12pin WEIDMÜLLER BLZ 7.62HP/12/180F |
Power supply of the control part | 1 x 5pin WEIDMÜLLER BCZ 3.81/05/180F |
Motor connector | 1 x 6pin WEIDMÜLLER BLF 7.62HP/06/180F |
EMI FILTER | |
Recommended type | NCZXX3P49-04 |
Static brake power
* Without power supply for the servomotor static brake (from 0.5 to 1A for the TGN series) and digital outputs (up to 6 x 300 mA).