| Input voltage (VAC - 50/60 Hz) |
1 x 230 VAC |
| Maximum input current (AC) |
16 A |
| Output voltage (DC) |
320 VDC |
| Maximum continuous output current (DC) |
10 A |
| Maximum short-term output current (DC, 1s) |
15 A |
| Installed power consumption for S1 operation |
3,2 kVA |
| Maximum braking power (internal resistor) |
100 W |
| Maximum braking power (external resistor) |
3 200 W |
| Losses at maximum output power |
80 W |
| Overcurrent protection |
16 A (char. Z, dual) |
| Protection level |
IP20 |
| Ambient operating temperature |
0 ~ 40 °C |
| OUTPUTS |
|
| RDY digital output (contact) |
Max. 28 VDC / 700 mA |
| ERR digital output (contact) |
Max. 28 VDC / 700 mA |
| SIGNALING |
|
| LED signaling |
1x green (Ready) 1x red (Error) |
| CONNECTORS |
|
| Mains connector |
1 x 3pin PHOENIX PC 5/ 3-STCL1-7,62 |
| DC bus connector |
1 x 8pin PHOENIX PC 5/ 8-STCL1-7,62 |
| Digital outputs connector |
1 x 4pin WEIDMÜLLER BCZ 3.81/04/180 SN BK BX |