Parameters

POWER SUPPLY
Control voltage 24 VDC ± 10 %, 400 mA*
Power supply voltage 0–48 VDC
Installed power consumption for S1 operation 2,4 kVA
Constant current on one axis 50A
Maximum output current (max. 5s) 100 A
Losses at rated load 30 W
Protection level IP20
Ambient operating temperature 0 ~ 40 °C
COMMUNICATION
CAN 4pin WEIDMÜLLER B2CF 3.50/04/180
FIELDBUS IN/OUT 100/1000 Mb/s, 2x RJ45
ETHERNET UDP (service) 100/1000 Mb/s, RJ45
Inputs/outputs
2 AI, 8 DI, 6 DO 1x 22pin WEIDMÜLLER B2CF 3.50/22/180
SIGNALING
LED display Error message, 2x7 LED segment
LED signaling 1x green (SERVO OK)1x red (SERVO ERROR)
OTHER CONNECTORS
Power supply of the power section 2 x Erni screw M5 PRESSFIT
Power supply of the control part 1 x 5pin MOLEX micro-lock, 505570-0501
Motor connector 3 x Erni screw M5 PRESSFIT
Static brake connector 1 x 4pin MOLEX micro-lock, 505570-0501
Feedback connector 2x 8pin WEIDMÜLLER B2CF 3.50/08/180
External encoder 1x 12pin WEIDMÜLLER B2CF 3.50/12/180

Static brake power

* Without power supply for the servomotor static brake (from 0.5 to 1A for the TGN series) and digital outputs (up to 6 x 300 mA).