Parameters

POWER SUPPLY
Control voltage 24 VDC ± 10 %, 2 A*
Power supply voltage 0 ~ 560 VDC
Installed power consumption for S1 operation 11 kVA
Constant current on one axis 10 A
Continuous total current when operating two axes 16 A
Maximum output current (max. 5s) 2 x 20 A
Losses at rated load 150 W
Protection level IP20
Ambient operating temperature 0 ~ 40 °C
COMMUNICATION
CAN 4pin WEIDMÜLLER B2CF 3.50/04/180
FIELDBUS IN/OUT 100/1000 Mb/s, 2x RJ45
ETHERNET UDP (service) 100/1000 Mb/s, RJ45
Inputs/outputs
2 AI, 8 DI, 6 DO 1x 22pin WEIDMÜLLER B2CF 3.50/22/180
SIGNALING
LED display Error message, 2x7 LED segment
LED signaling(axis 1 and 2 separately) 1x green (SERVO OK)1x red (SERVO ERROR)
OTHER CONNECTORS
Power supply of the power section 1 x 3pin WEIDMÜLLER BLZ 7.62HP/03/180LR
Power supply of the control part 1 x 5pin WEIDMÜLLER BCZ 3.81/05/180F
Motor connector 2 x 6pin WEIDMÜLLER  BLZ 7.62HP/06/180LR
Feedback connector 2 x 8pin WEIDMÜLLER B2CF 3.50/08/180
External encoder 1 x 12pin WEIDMÜLLER B2CF 3.50/12/180
EMI FILTER
Recommended type Filter already inside of TGS-560-25/50

Static brake power

* Without power supply for the servomotor static brake (from 0.5 to 1A for the TGN series) and digital outputs (up to 6 x 300 mA).