| Control voltage |
24 VDC ± 10 %, 400 mA |
| Power supply voltage |
0–48 VDC |
| Installed power consumption for S1 operation |
2,9 kVA |
| Constant current on one axis |
60 A |
| Maximum output current (max. 5s) |
125 A |
| Losses at rated load |
60 W |
| Protection level |
IP20 |
| Ambient operating temperature |
0 ~ +40 °C |
| COMMUNICATION |
|
| CAN |
4pin WEIDMÜLLER B2CF 3.50/04/180 |
| FIELDBUS IN/OUT |
100/1000 Mb/s, 2x RJ45 |
| ETHERNET UDP (service) |
100/1000 Mb/s, RJ45 |
| I/O |
|
| 2 AI, 8 DI, 6 DO |
1x 22pin WEIDMÜLLER B2CF 3.50/22/180 |
| SIGNALING |
|
| LED display |
Error message, 2x7 LED segment |
| LED signaling |
1x green (SERVO OK)1x red (SERVO ERROR) |
| OTHER CONNECTORS |
|
| DC BUS (+DC, -DC) |
2 x Pressfit M5 |
| Logic supply |
1 x 5pin Molex Micro-Fit 3.0 – 436450500 |
| Motor connection |
3 x Pressfit M5 |
| Static brake + motor thermistor |
1 x 4pin Molex Micro-Fit 3.0 – 430250400 |
| Feedback |
2x 8pin WEIDMÜLLER B2CF 3.50/08/180 |
| External encoder |
1x 12pin WEIDMÜLLER B2CF 3.50/12/180 |